X700 Multifunction Field Communicator Specification Table

CategoryItemSpecification
BrandBrandSUPCON
AppearanceStyleHandheld, orange - black shell, foldable stand; graphical touch screen
Field CommunicatorHART CommunicationConfigures/calibrates/diagnoses 1,500+ HART devices; compatible with HART5/6/7
Favorite MenuOne - key access to target menus during HART calibration
Power DistributionPowers transmitters (DC voltage) and positioners (DC current)
Calibrator ShortcutCalls up calibrator module via shortcut keys
Online UpdateUpdates HART DD files and apps online
APL Communication (Optional)Integrates APL bus for new APL field instruments
CalibratorMeasured/Output SignalsSupports current, voltage, frequency, pulse, resistance, RTD, thermocouple, etc
Special FunctionsSimulates 2 - wire transmitter mA output; 24VDC power for transmitters; dual - channel ops
Signal ProcessingSmall signal zeroing; ITS - 90 temp scale (°C/°F); cold junction compensation
Data RecorderRecords signals via trend graphs (up to 12h, exportable)
Signal Output5 waveform types; custom signal setting (preset/step/fine - tune/reset)
  • A: It is equipped with a 6000mAh lithium battery, and the typical working time is 11 hours. This battery capacity ensures that the device can operate for a full workday in most industrial environments without the need for frequent recharging.
  • A: Yes, it can operate within a temperature range of - 10°C to 50°C, and the storage temperature range is - 20°C to 70°C. This wide temperature range makes it suitable for use in various harsh climates and industrial settings where temperature fluctuations are common.
  • A: It is recommended to calibrate the device regularly according to the usage frequency. Under normal circumstances, calibrating once a year can ensure measurement accuracy. However, in applications where high accuracy is critical or in harsh environments, more frequent calibration may be necessary.
  • A: It supports serial RS - 485 communication, USB Type - C, Bluetooth, and also integrates an industrial APL bus communication interface and function module (optional). These multiple communication options provide flexibility and compatibility with different industrial communication systems and devices.
  • A: The protection class is IP54, which means it is protected against dust ingress ( dust ingress that will not interfere with operation) and water splashing from any direction. This makes it suitable for use in industrial environments where there may be dust, moisture, or water splashes.
  • A: Yes, there are optional accessories available. For example, the APL converter (model EMDA) can be used to expand the handheld device's functionality, enabling connection to APL instruments' wiring terminals or APL bus exchangers' Spur port side for APL instrument calibration configuration. Additionally, the high - precision cold - end temperature sensor is an accessory for the X700HM - Ex model.
  • A: The accuracy of thermocouple/thermal resistance measurements and outputs depends on the specific model and range. For example, in thermocouple simulation output, the accuracy is within strict tolerances to ensure accurate simulation of thermocouple signals for calibration purposes. The device's thermal resistance/thermocouple scale query functionality also aids in precise temperature - related measurements.
  • A: Yes, it can record signal measurement or output values for up to 12 hours with configurable record intervals. This makes it suitable for long - term monitoring and data collection in industrial processes, allowing for comprehensive analysis of process trends and equipment performance.
  • A: First, connect the communicator to the HART device using the appropriate cables and accessories. Then, use the HART communication function to access the device's configuration menu. From there, you can perform online configuration tasks such as setting parameters, calibrating the device, and conducting non - intrusive diagnosis. The favorite function can also be used to quickly access frequently used device menus during HART calibration for improved operational efficiency.
  • Description images
    Intrinsically Safe X700 EX Field Communicator Analysis Instrument for Oil & Gas Facilities Testing Equipment
    Intrinsically Safe X700 EX Field Communicator Analysis Instrument for Oil & Gas Facilities Testing Equipment
    Intrinsically Safe X700 EX Field Communicator Analysis Instrument for Oil & Gas Facilities Testing Equipment
    Intrinsically Safe X700 EX Field Communicator Analysis Instrument for Oil & Gas Facilities Testing Equipment
    Packaging and fulfilment
    • Step 1

      Payment and order readiness

      Minimum order: 1 Units

      Payment terms, specifications, and order details are confirmed before preparation begins.

    • Step 2

      Preparation

      Lead time will be confirmed with your quotation.

    • Step 3

      Packaging and dispatch

      Packaging details are available on request.

      Final packing, freight, and delivery dates are confirmed before dispatch.

    Technical specifications
    Minimum order
    1 Units

    Customer reviews

    0.0 (0)

    No reviews yet

    Be the first customer to review this product.

    Write a review

    Up to 5 JPG, PNG or WebP images; 5 MB each.

    Request custom sourcing

    Can’t find what you’re looking for? Share the requirement and our sourcing team will find the right industrial product.

    Best-match productsCompetitive quotesFast turnaround
    Request custom sourcing

    Upload your requirements

    Upload your BOM, BOE, RFQ or requirement list and get one consolidated response.

    XLS, XLSX, CSV, PDF, DOC or images · Max 10MB each or drag and drop
    XLSX
    Files are sent securely.