Factory 400kw Electricity Generator Price with perkins 500kva Generators Price Groupe Electrogene Perkin Moteur diesel 500kva
Certification & Brands
Product Description
| Diesel generator Details | |
| Model | JHP-500GF |
| Power | 400kw/500kva |
| Frequency | 50Hz (60Hz is available) |
| Voltage | 230/400V(voltage can be customized) |
| Optional Type | Open/soundproof/trailer |
| Silent Size | 4700*2100*2450mm |
| Weight | 4920kg |
| With Diesel Engine | |
| Brand&model | Pekins 2506C-E15TAG2 |
| Standby Power | 435kw |
| Cylinders | 6 in line arrangement |
| Bore*Stroke | 137*171mm |
| Displacement | 15.2L |
| Lubrication Oil Capacity | 62L |
| Fuel Consumption at 100% Load | 208g/kw.h |
| Speed Governor | ECU |
| With Alternator | |
| Optional Brands | Stamford/Leroy Somer/Mecc Alte/Marathon/ABB |
| Exciter type | Single bearing,brushless,Self-excited |
| Power factor | 0.8 |
| Voltage adjust range | ≥5% |
| Insulation Grade | H |
| Protection Grade | IP23 |
Detailed Images
a leading Chinese diesel generator set manufacturer, boasts years of industry experience. Here are our key features
1. Corporate Strength & Production Assurance
Large - scale Production: A 35,000 - sq - m modern factory with 5,000 units (sets) annual capacity and over 180 - million - yuan total assets.
R & D Support: Advanced low - noise test center and 10 - year spare parts warehouse ensure product performance and long - term stability.
Quality Certifications: ISO 9001:2008 and EPA certified.
2. Product Range & Tech Advantages
Full - spectrum Offerings: 7 generator set series (low - noise
High - performance Specs: Diesel sets use domestic/imported engines (e.g., MTU, Cummins) with all - copper generators, featuring 197g/kW·h low fuel consumption, < 65dB noise, and 50/60Hz dual - frequency output.
Customization: Flexible voltage, frequency, and brand (e.g., Stamford, Marathon) customization for one - stop power solutions.
3. Global Reach & Customer Trust
Wide Applications: Products serve global clients in comms, ports, highways, hospitals, hotels, military, excelling in industrial backup, infrastructure, and emergency power.
International Acclaim: MTU series with Mercedes - Benz tech, 200 - 2400kW power, 24,000 - 30,000 - hour first - overhaul, suitable for extreme conditions.
4. Service & After - sales
Quality Control: 100% factory inspection, ensuring "zero defective products out".
Global Support: 3 - year warranty, 24/7 tech response, regular checks, and fast repairs across Europe, Middle East, South America, etc.
Logistics: Leverage International's local logistics for efficient delivery and regional customization.
5. Cooperation Edge
Price - competitive: Factory - direct sales for top - tier cost - effectiveness.
Packing & Delivery
Installation Onsite
1.How to Calculate Diesel Generator Fuel Consumption?
Diesel Generator fuel consumption can be calculated by multiplying the generator's rated power (kW) by the specific fuel consumption rate (L/kWh) provided by the manufacturer. For example, if a 50 - kW generator has a rate of 0.2 L/kWh, the fuel consumption is 50×0.2 = 10 L/h.
2. How to Choose the Correct Diesel Generator Size for My Needs?
First, calculate your total power requirements by adding up the wattages of all the devices you'll power. Then, consider a diesel generator with a capacity 20 - 30% higher to handle startup surges and ensure reliable operation.
3.How to maintain generator in high humidity?
Keep It Dry: Store the generator in a dry, well-ventilated place. Use dehumidifiers or moisture-absorbing materials around it.
Inspect Regularly: Frequently check for signs of condensation, rust or corrosion on the generator's surface and components.
Protect Electrical Parts: Apply anti-corrosion sprays on electrical connections and components. Ensure all covers and enclosures are properly sealed.
Check Air Intake: Clean the air filter often to prevent moisture and dirt from entering the engine.
Run Periodically: Operate the generator regularly to keep components dry and lubricated, which helps prevent moisture buildup.
4.Diesel Generator Maintenance Checklist
Diesel generator Daily: Check fluids, look for leaks.
Weekly: Test battery, run generator briefly.
Monthly: Inspect air & fuel filters.
Quarterly: Change oil & filter, check belts.
Annual: Tune - up engine, do load bank test.
5.Silent Diesel Generator Buying Guide
Consider diesel generator power output based on your needs, noise level suitable for the environment, fuel efficiency, build quality, and additional features like control panels. Also, check the brand reputation and after - sales service.




-
Step 1
Payment and order readiness
Minimum order: 1 Units
Payment terms, specifications, and order details are confirmed before preparation begins.
-
Step 2
Preparation
7 days
-
Step 3
Packaging and dispatch
Packaging details are available on request.
Final packing, freight, and delivery dates are confirmed before dispatch.
Customer reviews
No reviews yet
Be the first customer to review this product.
Write a review
Request custom sourcing
Can’t find what you’re looking for? Share the requirement and our sourcing team will find the right industrial product.