Key attributes

View all
Type
Flameproof Digital Multi-Point Temperature Display
Temperature Resolution
1°C
Field of View
None
Probe length
None
Infrared resolution
None
Material
Cast aluminum with corrosion-resistant paint coati
Product description

Highlights at a glance

  • Ex d IIC T6 Gb and Ex d IIB T6 Gb dual flameproof markings cover the widest range of hazardous gases including hydrogen acetylene and general industrial gases
  • CCC compulsory certification plus CNEx flameproof certification meet domestic mandatory compliance for hazardous area equipment
  • Supports 1 to 8 temperature measuring channels in a single unit ideal for monitoring multiple bearings or process points simultaneously from one display head
  • Real-time scanning display 6 seconds per point rotates through all channels providing comprehensive monitoring without operator intervention
  • Multiple output options including dry contact relays Pt100 retransmission 4-20mA current and RS485 Modbus communication for flexible system integration
  • Dual alarm setpoints T1 and T2 configurable as unified or separated allows tailored alarm logic for different process points or equipment groups
  • 1.0 accuracy class provides reliable measurement performance suitable for industrial process control and safety monitoring applications
  • Frequently asked questions

    GWD carries: - Ex d IIC T6 Gb and Ex d IIB T6 Gb flameproof certifications (dual gas group) - CCC compulsory product certification ( mandatory) - CNEx national flameproof certification - Patent No. ZL200930117210.9 for the housing structure Important note: GWD does NOT carry ATEX, IECEx, EAC, SIL3, or PAC certifications. For projects requiring those international certifications, please consult us for alternative solutions. Certificate copies are provided upon serious inquiry.

    GWD supports 1 to 8 temperature measuring points in a single unit: - 1 point: simple single-bearing or single-pipeline monitoring - 2 points: front and rear motor bearings - 3-5 points: motor bearings plus stator windings (typical large explosion-proof motor configuration) - 6-8 points: complex multi-bearing equipment or multi-process monitoring All measuring points share a single LCD display head with real-time scanning at 6 seconds per point.

    Per the manufacturer model code convention GWD-[points][output][power]: - GWD = Flameproof temperature display and controller series - 5 = 5 measuring points - 2 = Separated alarm output configuration - B = AC 220V 50Hz power supply So GWD-52B = 5-point flameproof digital temperature controller with separated alarm outputs powered by AC 220V.

    GWD provides multiple output options configurable per order: 1. Relay Contact (dry contact alarm outputs): - Unified alarm: all points share T1 upper alarm and T2 high-high alarm setpoints - Separated alarm: points divided into two groups with independent setpoints 2. Pt100 RTD Retransmission: up to 2 channels of Pt100 signal output (requires dual-element Pt100 sensor) 3. 4-20mA Current Output: 1 channel of analog current output (requires dual-element Pt100 sensor)

    Both options provide two alarm setpoints (T1 upper alarm and T2 high-high alarm) with dry contact relay outputs: UNIFIED ALARM: - All measuring points share the SAME T1 and T2 setpoints - Example for 5-point GWD: all points trigger T1 alarm at 80°C and T2 alarm at 135°C - Simpler logic, suitable when all monitored points have similar temperature limits SEPARATED ALARM: - Measuring points divided into TWO groups with INDEPENDENT setpoints

    Per Ex d IIC T6 Gb and Ex d IIB T6 Gb markings: - Zone 1 (occasional explosive gas atmosphere): APPROVED - Zone 2 (rare explosive gas atmosphere): APPROVED - Zone 0 (continuous explosive gas atmosphere): NOT applicable Ex d is flameproof not intrinsically safe Gas group coverage: - IIC marking: covers hydrogen H2 and acetylene C2H2 (most demanding gases) - IIB marking: covers ethylene and most general industrial gases

    Installation procedure (per Chinese hazardous location electrical installation code): 1. Verify nameplate Ex marking matches installation environment 2. Use copper shielded cable with cross-section at least 0.2 sq mm (minimum cable outer diameter Phi 6 mm) 3. Open the junction box, loosen cable gland compression nut, connect cable to terminal blocks 4. Replace junction box cover and tighten all four corner bolts 5. Reliably ground the equipment via the external grounding screw

    Standard documentation: - Ex Certificate (CNEx flameproof certificate) - CCC Certificate - Factory Quality Inspection Report - Calibration Certificate (traceable) - Patent Certificate copy (ZL200930117210.9) - Certificate of Origin (CCPIT) - User Manual (Chinese and English)
    Description images
    Product detail
    Product detail
    Product detail
    Product detail
    Packaging and fulfilment
    • Step 1

      Payment and order readiness

      Minimum order: 10 Units

      Payment terms, specifications, and order details are confirmed before preparation begins.

    • Step 2

      Preparation

      30 days

    • Step 3

      Packaging and dispatch

      Ocean freight via Maersk · Approx. shipping fee: $ 0.84 for 1 unit · Transit time: Est. 17-24 days

      Final packing, freight, and delivery dates are confirmed before dispatch.

    Technical specifications
    Other details 29 fields
    Type
    Flameproof Digital Multi-Point Temperature Display
    Temperature Resolution
    1°C
    Field of View
    None
    Probe length
    None
    Infrared resolution
    None
    Material
    Cast aluminum with corrosion-resistant paint coati
    IP Rating
    IP66
    Display Type
    Pt100 retransmission
    Communication Interface
    None
    Additional Function
    None
    Thermal color palettes
    None
    Warranty
    1 Year
    Customized support
    OEM, ODM
    Model number (Specification)
    GWD
    Place of origin
    China, Henan
    Product Type
    Flameproof Digital Multi-Point Temperature Display and Controller
    Hazardous Area Marking
    Ex d IIC T6 Gb / Ex d IIB T6 Gb
    Measurement Range
    0 to 200 °C
    Number of Measuring Points
    1 to 8 channels - specify per order
    Display
    LCD with backlight - real-time scanning display, 6 seconds per point
    Housing Material
    Cast aluminum with corrosion-resistant paint coating
    Cable Entry Direction
    Left side (default) or right side - specify when ordering
    Working Ambient Temperature
    20 to +40 °C
    Warranty period
    1 year
    Country of origin
    China (Henan)
    Selling Units
    Single item
    Color (Product option)
    Std Cast Al Housing
    Accuracy (Product option)
    ±1°C
    Temperature range (Product option)
    0-200C / 32-392F
    Lead time
    30 days
    Minimum order
    10 Units

    Customer reviews

    0.0 (0)

    No reviews yet

    Be the first customer to review this product.

    Write a review

    Up to 5 JPG, PNG or WebP images; 5 MB each.

    Request custom sourcing

    Can’t find what you’re looking for? Share the requirement and our sourcing team will find the right industrial product.

    Best-match productsCompetitive quotesFast turnaround
    Request custom sourcing

    Upload your requirements

    Upload your BOM, BOE, RFQ or requirement list and get one consolidated response.

    XLS, XLSX, CSV, PDF, DOC or images · Max 10MB each or drag and drop
    XLSX
    Files are sent securely.